The
simultaneous monitoring and warning of up to five gas hazards,
such as: |
|
| 1. |
Ex
(0 - 100% LEL) |
| 2. |
CO2
(0 - 25% by volume) |
| 3. |
O2
(0 - 25% by volume) |
| 4. |
H2S
(0 - 100 ppm) |
| 5. |
CO
(0 - 500 ppm) |
|
| - |
operation
of the instrument is simple with three large buttons. Further
features can be programmed in as needed for easy use with our
new flexible operating menu (FLEXMEN), for example: |
|
| 1. |
Fresh-air
callibration, |
| 2. |
Changing
over from % LEL to % |
|
|
by
Vol when measuring methane. |
| - |
the
back illuminated, full graphics display, shows up to 8 lines of
20 digits. This display clearly leads the user through a simple
and well structured operating menu in plain text. The current
gas concentrations of all 5 measuring channels are displayed
simultaneously while measuring. |
| - |
display
can be illuminated at the push of a button |
| - |
extremely
loud audible alarm signal (85 dB(A), at a 30 cm distance) |
| - |
clearly
visible red alarm light with 3 LEDs |
| - |
optimized
housing design which is both: stable in an upright position
(area monitoring for several people) and wearing close to the
body (monitoring of individuals) |